Neurobit Runtime

Version information

Ver. 3.7

  • Solution to a bug, which occasionally prevented an application from loading of Neurobit driver file (NeurobitDrv.dll).
    In BioExplorer it caused disappearance of Optima device from Device Manager and made impossible to add the device again until system restart.

Download for BioExplorer, BioEra, eBioo, Mindfulness Technology and Neurobit Recorder.

Download for BrainBay, OpenVIBE and applications created by users.

Ver. 3.6

  • The channel profile "EEG 250sps" has been added. It simplifies configuration of EEG measurement at 250 samples per second (2 fold higher, than for "EEG" profile available so far).

  • For "EEG" and "EEG 250sps" channel profiles the "Common reference" field is now set to "Reference 1" by default. This setting is suitable for referential derivations (used most commonly).

Ver. 3.5

  • Diagnostic file NeurobitDrv.log is now created. It is placed in the main folder of an application. Size of the file is limited to about 1MB.

Ver. 3.3

  • Neurobit device settings, which have been already set by a superior configuration means of an application, can now be locked (not available for manual changes) in the settings window of the Neurobit Driver. At the moment this feature is used by OpenVIBE software.

Ver. 3.2.3

  • "Power mains frequency" setting (used e.g. by Neurobit Optima) is now read from the system registry (and not from design or configuration file maintained by an application). And it is set automatically, based on user's geographic location (country) set in the system ("Control Panel"/"Regional and Language Options"/Location), when the Neurobit Driver starts the first time, or when a user has changed geographic location in the system since previous start of the driver.

    Nevertheless, user can still change power frequency selection. It may be necessary e.g. when traveling and location info in the system is not up-to-date, or in Japan, where two power frequencies are in use.

    This setting is now common for all applications using Neurobit Driver and all users of a given computer.

  • Removed bug: in rare cases the application crashed while changing a channel setting having dependencies (e.g. "Channel profile" or "Channel function" influencing other channel parameters).

  • For interoperation with BioExplorer application (v. 1.6 or earlier), which does not store Neurobit device settings along with a design, two buttons facilitating device configuration have been added at the bottom of the window:

    • "Load" settings from file,
    • "Save" settings in file.
    Notes:
    • Make sure that loaded configuration is suitable for current BioExplorer design (e.g. that channels are configured to measure EEG for a neurofeedback design).
    • Only configuration file for current device model (selected in the Device Manager of the application) can be loaded.

  • For Neurobit Optima devices, information about upper frequency limit of temperature signal band has been updated according to changes in Optima firmware ver. 1.1.

  • The "Sum disconnected" option is checked by default for the "Temperature" channel profile.

  • Impedance bars on Test tab are now more accurate.

  • Background colors in device settings window have been corrected for eBioo application.

Ver. 3.1

  • Status tab has been added in the device settings window during normal measurement session. It enables to see detailed status (of each measurement channel) if it is not shown directly in an application window.

  • Test tab is now hidden in the device settings window during normal measurement session.

  • When "Device address" field is emptied manually, the default address is automatically set.

  • Application can now read device serial number.

Ver. 3.0.7

  • Device settings window is now shown in front of BioEra windows.
    (No influence on other applications.)

Ver. 3.0.6

  • Channel parameter Common reference added for Optima devices. It informs of external connection of "-" input of a given channel to a common reference electrode. Its suitable selection is required for correct results of electrode-skin impedance tests for such inputs. However, that selection brings result for Optima devices with firmware version 1.0.1 or newer (nevertheless, compatibility with Optima firmware 1.0 is preserved).

  • Help file for Device services has been included.

Upgrade instructions

  1. Download the latest driver version for your application using one of the links below.

  2. If you have running an application supporting Neurobit equipment, exit it.

  3. System administrator rights are required in this step. Unpack the downloaded archive to a suitable folder of your application, overwriting existing files.

    Folders for driver files depending on an application (in relation to "Program Files" or "Program Files (x86)" folder):

    application folder
    BioExplorer BioExplorer
    BrainBay BrainBay\NeurobitRuntime
    BioEra Pro,
    Mindfulness Technology
    BioEraPro\drivers\neurobit
    eBioo eBioo
    Neurobit Recorder Neurobit\Recorder